networ cabling,cable management

Things to Avoid in Running Network Cabling

28 Mar 2015

Date cabling,cable managementWhat can cabling that has not been installed properly do?


It can lead to a lot of negative outcomes such as paralyzed network performance, maintenance troubles and hidden costs. Network cabling can be  especially troublesome if it is installed by individuals without the proper knowledge and tools. When it comes to twisted pair cabling, there are many factors that you need to consider.


In the past, many companies installed different cable systems since twisted pair cabling was expensive. At present, full installation is still costly although a greater part of the expense is labor since raw cables is not pricey. Cable management is another concern. Use of ladder racks means additional cost but it reduces upkeep. Also be sure you label cables and to make use of color codes.


Unshielded twisted pairs are more practical in terms of usage. Magnetic fields are produced by low voltages that pass through your cables. This is a vital property of the communications cycle. And if you run unshielded cables along with electrical wires, the magnetic field can be interrupted. The communications becomes corrupted or noisy. You can expect that transmissions will not make it from one point to the other. Another possibility is that transmission rates will become slower. The cables should be perpendicular with electrical lines instead with the electric wires inside of shielded tubes at cross points.


Do not attempt to run cable alongside fixtures that create “noise”. Fluorescent lamps, motors and devices that generate electrical or magnetic interference will distort your cabling infrastructure. Install a data cable conduit that will create a buffer from these hazards. Also figure out the total distance of each cable. This is usually up to 100 meters. However, if cabling data rates reaches 10 to 40 GBPs, be attentive about distance restrictions related to the kind of cabling you plan to use. If you will run 10 GBPs for a maximum of 100 meters over twisted pair cabling, it is best to use Category 6 cabling.



Be aware of local codes.


This is important for safety concerns. In many areas, using PVC-covered cables is not allowed in air-handling spaces. When PVC burns, there is toxic emission that may prove dangerous to firefighters and other safety personnel who will try to navigate the location during emergencies. Failure to follow rules can lead to fines and forced replacement of cabling infrastructure. Contractors must be mindful of these regulatory standards.

Data Cabling,Structured Cabling, Cabling Design-Washington DC

Things to Avoid in Running Network Cabling

28 Feb 2015

What can cabling that has not been installed properly do?


network cabling,Data CablingIt can lead to a lot of negative outcomes such as paralyzed network performance, maintenance troubles and hidden costs. Network cabling can be  especially troublesome if it is installed by individuals without the proper knowledge and tools. When it comes to twisted pair cabling, there are many factors that you need to consider.


In the past, many companies installed different cable systems since twisted pair cabling was expensive. At present, full installation is still costly although a greater part of the expense is labor since raw cables is not pricey. Cable management is another concern.

Read More

Structured Cabling, Cabling, Washington DC

Practical Pointers in Network Cabling

20 Feb 2015

StructuredCablingFiberOpticsCat6a10GigNetworking cabling is not a simple task. It entails expertise and attention to detail. What are valuable insights that network technicians need to know about for effective cabling and installations?



Cable length is essential.


The telecommunications standards prescribed by the Telecommunications Industry Association and Electronic industries Alliance (TIA-EIA) states that maximum distance end to end of cables should be no more than 100 meters.

Read More

CAT 6a,network cabling, DC

Designs of Optic Fiber Cables

12 Feb 2015

network cabling,Data CablingmOptical Fibre CableOptical fiber cabling is made up of a fiber core and a protective layer. The shield is typically coated with a polymer. It protects the cable from damage and does not contribute to optical wave guide properties. The coated fiber is a durable synthetic resin serving as a support for the cable’s core. Protective jacket layers are added depending on the cabling application.



Fiber over Copper


Fiber has benefits over copper. Fiber optic transmission does not emit Radio Frequency Interference or RFI. This guarantees secured communications since light waves can't be easily intercepted. On the contrary, copper wires give off signals that interfere with other electronic equipment. That is why utility firms now run power lines with fibers

Read More

Structured Cabling,Office Cabling

Cabling Pointers for Effective Data Center Management

5 Feb 2015

Structured Cabling,Office Cabling,datac enterThe data center supports the lifeblood of corporate enterprises. Communications stop due to the malfunction of this facility. Unfortunately, multiple issues can affect the data hub and incorrect cabling can be one of them. Planning is the key to boosting the efficiency of data center cabling.



 Here are some things to consider:



  1. Measure cables with care. Otherwise, you produce a twisted “rat's nest” and an unnecessary waste of money.

  2. Put a label on both tips of your cables which include patch and short runs. This will be useful if you need to test a cluster of circuits. It will not be confusing if you unplug several patch cables. You know where each single cable is connected. The marking system must be consistent at all times.

  3. Never rush on termination of cables. And redo in cases where cables lose connectivity. Avoid purchasing and using cheap products. You will end up spending more in the long-term.

  4. Test the cables first and make sure it passes the mark for continuity.  If not, you have to do it all over again. And always use a high-quality tester to avoid unwarranted work.

  5. Patch cables must be kept short. Remember that rack servers are only one foot away from each other. Patch cables with a length of three feet are definitely not appropriate. Combine testing and terminating capabilities to make sure that patch cables connect accurately. Additional lengths will cause a lot of twisting.

  6. Come up with a color coding technique. A single color is ideal for patch cables and cable runs. However, it is possible to utilize specific color cables for specific purposes. Avoid random colors. It will be easier to follow cable functions and resolve problems if your color has a purpose. Blue for data, white for voice is a common standard.

  7. Your design must be cable-friendly. Do not put a rack in a place where it is not possible to run your cable effectively. You may end up with cables dropping from the ceiling or scattered on the floor. Expansion should also be in your planning so you know when and how to make adjustments.

  8. Separate electric wires from Cat5/6 cables. Power lines can distort communications. The effects will be to have connection and data transmission issues that can result in data corruptions.

  9. Be careful about excessive temperature. Make sure that the cables are cool and not hot since this can result in cabling decomposition. The data center should be designed in a way that servers and networks are always at a comfortable temperature.


If you need help in designing your structured data cabling system, please feel free to call or contact us. We do free cabling site proposals.

Data Cabling ,Cat5e ,Cat6/6a ,Cabling ,Structured Cabling

Network Infrastructure Planning

28 Jan 2015

What is a network?Full_Network


The network is classified as a group of hardware and software components that connect devices within a company and link that entity to other companies in the world-wide web. The hardware for networking consists of network interface cards, computers, routers, switches, patch panels and cables. Software refers to network services and protocols that facilitate communications. The hardware components should be installed and configured before the software and operating systems are initiated. Network communications serve as the core foundation of the whole system. It makes up the services that build the network’s framework. The key is to determine the infrastructure based on the objectives that you have set so the architecture can scale up as a companies needs grow.



The Operating Systems


Begin by understanding the current setup. This will allow you to establish how to plan for your operational targets and objectives. Draw a full map of the current network. Include these all cabled connections, server information, location of devices in the network, and all of the users.  Complete this inventory first. Then, proceed with reviewing all available information in combination with the future goals. This will enable you to fully understand the required changes needed for deployment.


The operating systems or OS installed on computers make up the primary software components in a cabling infrastructure. The OS contains protocols that facilitate network communications. It also consists of applications and services that secure the data. Conventional features include connectivity, security, control of access, and routing/switching functions. There should an existing network before installing servers to support applications. These consist of file, print, web, messaging, application, and database servers.



Meticulous Planning



  • Document the physical hardware and software components

  • Decide on the actual location of each components.

  • Determine configuration requirements.

  • Buy, assemble and mount the hardware.

  • Install and configure your OS, apps as well as other software.


Be sure to understand the network’s physical design. If there are multiple heavy or data intensive workloads, servers will need more bandwidth and connections to deal with the data traffic. Network resources need to  allocated among the numerous applications which mean that vital applications can affect performance considerably. Planning becomes an integral component of development and should be specific to the business plans.


Keep track of existing workloads and use performance results as a reference. There should be proper tests to determine the performance of your network. Speculation is not advisable because that can cause mistakes and overspending.


As always, Progressive Office is available to assist with project planning. Please call or email us anytime.


 
Structured Cabling,,Office Cabling.connectors

Important Facts About Cabling Infrastructure

23 Jan 2015

NetworkStructured Cabling,,Office Cabling.connectors cabling that has not been installed properly may result in various communications issues. Even minor problems such as a connector that has not been terminated properly can prevent Power over Ethernet from performing well.



Wiring Standards


See to it that you use appropriate wiring patterns which are T568a and T568b. Refrain from bringing together T568a and T568b in the same cable. And always use premium quality Cat6 or Cat5e cables. We prefer solid over stranded wire.

Read More

Structured-Cabling,Data Cabling

Essential Issues in Design of Structured Cabling Systems

13 Jan 2015

Structured-Cabling,Data CablingStructured cabling systems (SCS) refers to the local area network  cabling system designed exclusively to fit a company's requirements. It combines data, voice, video, and management systems sometimes including alarm and security. SCS insures that all of this information is transmitted promptly and efficiently. The structured cabling system normally includes transmission products with engineering design rules that create a stable transmission system.



Network Foundation


The structured cabling system is said to be the groundwork of a successful building and office setup. It is also the fundamental foundation on which all other equipment relies on.

Read More

Structured-Cabling,Data Cabling

Common Blunders to Avoid

7 Jan 2015

CableStructured-Cabling,Data Cabling,fiber-optics networking has evolved a great deal. It is now mandatory for companies to invest in structured cabling systems that can support a complex operation. That is why many corporations have shifted to fiber optic communications from the traditional copper cabling systems. However, it is important to plan the infrastructure carefully and anticipate some problems that may come along the way.



Replacement in Stages


Doing everything hastily and simultaneously is a problem.
Read More
Network Cabling ,Data Cabling, Fiber-optic cable,New York City

Unique Properties of Fiber Optic Cabling

30 Dec 2014

Network Cabling ,Data Cabling, Fiber-optic cableFiber optics is capable of resolving many issues in data communications. However, computer data is normally transmitted over ordinary copper cables because it's adequate at lower speeds and shorter distances. It is not advisable to utilize fiber cable in these ordinary instances because of the high costs.


Fiber is impervious to electromagnetic interference because the signals are transmitted as light impulses. That means that Electromagnetic Interference (EMI) is not possible. Light waves are not effected by magnetism. This type of impediment can happen in coaxial and Cat5/6 cables because electricity can interfere with data signals over copper wires. Magnetic fields produce electrical current and this electromagnetic Interference is noise that can scramble data.


Fiber optic cabling also is much better at providing security of data since electromagnetic fields are not emitted around optical fibers. The data is restricted within the structure of the cable making it impossible to tap signals being communicated without cutting across the fiber. Emissions can not be easily intercepted. Hence, the fiber is by far most secure channel for carrying sensitive data.


Fiber is also a “non-conductive cable” because there is no metal in its design. It's a highly purified glass fiber.  While copper is a conductive cable that can attract power surges and unwanted current. With fiber, outdoor varieties are costly because these call for special strength. Therefore, fiber optic cable is usually more cost-effective for indoor use. With copper, it is also important to get rid of the current commonly known as ground loop. The metal cable can run into signal transmission distortions due to slight transmissions in electricity.


Fiber optics also does away with threats coming from sparks. The transmission of signals can be hazardous because of this phenomenon. Although the spark itself is not dangerous, it can lead to greater problems especially in industrial and chemical plants where the air is polluted by possibly dangerous vapors. Fiber cable does not generate sparks because it carries no electrical current.


Installation of fiber is less difficult because of its small size and flexibility. And fiber optic cables can pass along the same route as electric cable without producing any noise. The size, lightness and elasticity of fiber optic cables also makes them suitable for short-term or portable installations. And they transmit signals over longer distances too. Amplifying the transmission capability of copper wire cables makes them more unyielding. Thicker copper cables are also hard to mount in spaces where the cables have to pass through cable conduits and concrete walls.


Fiber optic means higher bandwidth too. It has the capability to transmit high-speed signals over lengthy distances without repeaters, unlike copper cables. The fiber optic’s range is not infinite but it is way more than copper cable.


If you need help in figuring out the ideal cabling topology, contact us or call 202-462-4290 for a free on-site survey and proposal.