Network cabling, NetworkTopologies.

Essential Facts About Cabling System

14 Dec 2014

Network cabling, NetworkTopologies.Your office cabling system is costly and complicated investment. It's also a commitment to an office design and structure that is not easy to modify. If you add more workstations later, new cabling might be needed.


Most offices have a structured cabling topology that hardwires the cables from wallplate to patch panel. With this system, modifications are less likely because the initial installaiont includes a planning process that should anticipate some expansion. By pre-wiring potential locations in an existing or newly-constructed building, future moves, additions or alterations are avoided. You can just transfer patched cables in the wiring closet. Also, it is critical to number the wallplates to match the corresponding patch panel number. This will make it much easier to relocate a workstation or to troubleshoot a connectivity problem.



There are several sub-systems to consider:



  • The Demark refers to the point where the Internet Service Provider's (ISP) data line comes to an end and hooks up with the cabling in the building.

  • The equipment room serves as storage for all apparatus and wiring integration points.

  • Backbone cabling are high-speed cables (typically Cat6 or fiber) that connect various floors or wall closets.

  • The horizontal cabling for links up the network space to individual wallplates. These are done through conduits and ceiling spaces on every level.

  • The telecommunications enclosures are wall or floor mounted cages that hold the network equipment; primarily the patch panels ands switches but also sometimes the server and Uninterruptible Power Supplies (UPS) too.


Installation and design of structured cabling is regulated by standards that identify the following:



  • Network data switches

  • Offices layout for voice & data communications for Cat5e or Cat6 cable

  • Fiber Optic cables for backbones

  • Modular connectors at the wallplate


These components will guide the layout of cables in order to fulfill the data access requirements of your office. All of the cables start at the patch panel on a mounted rack (about 19 inches wide) in the wall closet. From there, they traverse through the drop ceiling and down the walls to individual wallplates. Quite often a wallplate will host 2 or more connections. At the wallplate a short patch cable, usually 7 to 14 feet in length wil connect the computer, phone, printer or other networked device.


All cabling standards require that all of the eight conductors in Cat5, Cat5e and Cat6 cables are inter-connected in a precise color-coded pattern. The network cable connects each device but some devices can share a single cable. This is true for VoIP phones. Most VoIP phones have a jack for the network cable and then a jack on the phone for connecting the computer. This pass-thru enables the two devices to share one connection.

Network cabling, cables,shielding

About Ethernet Cables and Data Shielding

7 Dec 2014

Network cabling, cables,shieldingThe Ethernet network cable connects devices on a LAN (local area network) such as personal computers, switches and routers. These cables are typically Cat5 and Cat6. These cables provide the infrastructure that connects the PCs, printers, router/modem and other peripherals to a switch. The cables are made up of stranded or solid copper wires. Stranded wires are not as susceptible to fractures but are more difficult to terminate. Solid Cat5/Cat6 also is less susceptible to electrical interference. These shielded cables are made up of braided strands of copper wrapped in a polymer layer and spiral copper tape. The shield is applied across the splices.


An Ethernet cable can be compared to an electrical power cord in that it can only extend a limited distances because of the electrical transmission properties. Meanwhile, wireless technologies (Bluetooth and Wi-Fi or local wireless technology) have enhanced the reach of Ethernet in residential and enterprise networks. The standard Ethernet cable consists of four coiled pairs that terminate at the eight pins of the clipped connector or "RJ45" at both ends of  a cable. At the wallplate is simply the female end of the same connector. The cable is made up of unshielded (UTP) or shielded twisted-pair (STP) cabling.


Shielding is not selected automatically during installations. The answer is, it affords the protection required for certain environments although there are also some downsides. One is mass. The single-shielded cable made of Ethernet weighs approximately 12 percent more than the unshielded cable. The double-shielded version is roughly 30 percent heavier. You may be putting together dozens or perhaps hundreds of individual shielded twisted-pair cables along  a  ladders tray above the ceiling, under a floor, or at the back of panels. The aggregate weight of these cables can collapse the mounting bracket.


Cable flexibility is also an important issue. Take care when you pull the cables through  conduits. The cable shielding can make installation more difficult. The sole foil shield can crack while the sharp boundaries of the shield can scrape the insulation of individual wires. This can cut the wire and cause data transmission issues.



What are the shielding options?


You have a number of shielding choices in for your Ethernet network. The single-shielded cable has the lightest protection. Double-shielded cables contain a foil and plate shield. It can ensure better protection against electromagnetic or radio frequency interference and reduce issues related to cable relocation. High-flex industrial cables are fabricated and protected for uninterrupted applications. These have special jacket materials to address industrial and outdoor concerns.

Cat5e Cat6/6a Cabling,Office Cabling

Handling Cat5/Cat5e Cabling

19 Nov 2014

cat 5e,Network cabling, cables, Atlanta GAInformation Technology specialists have to choose the kind of cable to utilize for their networks. Cat5 has been one of the main choices for decades. This is because Cat5 supports 10/100 Ethernet which includes Fast Ethernet. In recent years, Cat5e has become the dominant choice for new cabling projects. And Cat5e cable is also backwards compatible. Your computers, phone and other network devices will work on Cat5e cable.


One handling issue is the electrical interference

Read More

Network Cabling Data Cabling

Fundamentals of Structured Cabling Systems

15 Nov 2014

structured cabling,  Network Cabling, Data CablingThe structured cabling system is a comprehensive structure of wiring and the related hardware involved. This system ensures a complete and reliable telecommunications infrastructure. This network has several  but mostly for providing telephone services or conveyance of data over a  computer network. This type of cabling system also connects to the internet at the demarcation point.



A quality structured cabling installation has these common elements:



  • It must fir the architectural configuration of the building that hosts  cabling installation

  • It made up of cable and connection fixtures

  • It connects equipment that cabling is setup to support

  • Can be designed to enable retrofitting and upgrading

  • Meets the objectives and requirements of the business

  • Is backed by a guarantee by the manufacturer and the installer


As installers, we use standardized techniques in the completion and upkeep of cabling systems. This is important to guarantee satisfactory system performance on a technically complicated infrastructure. The benefits of adhering to these standards are that they insure stability of connectivity after setup.



 Structured cabling installations may include:



  • Entrance facilities

  • Perpendicular and horizontal backbone conduits or cables

  • Horizontal lanes

  • Work area facilities

  • Equipment areas

  • Telecommunications racks and cabinets


A cabling connector refers to the mechanical device used in connecting a cable to a device or from one cable to another. The connector provides the coupling device that can minimize losses.  For fiber, it permits light signals to move from one connector to another. On the other hand, copper enables electrical impulses to be conveyed. It is important to properly align these  connectors to prevent connectivity breaks. Likewise, it should insure the efficient transmission of data. Connectors are crucial to the reliability of the total telecommunications network.


There are six subsystems in the structured platform. These are entrance facilities, equipment rooms, backbone cabling, telecommunication rooms and enclosures, the cabling, and the work area.  The first consists of cables, network boundary, hardware for connection, security devices, and equipment attached to the network cabling. Backbone cabling consists of subsystems that provide inter-connection between telecommunication, network equipment and access facilities.  Quite often these are the higher speed cabling components such as Cat6 and fiber that connect among the switches of an office.


Horizontal cabling connects from the desktops and phones to the telecommunications rooms and enclosures. The maximum horizontal cable length should be at no more than 100 meters. These desktop components extend out from the wall plate connection end of the horizontal cabling system to the equipment in the wall closet.


Call us if you need troubleshooting or if you have a need for cabling at your office due to expansion or relocation of your firm. We do free on-site surveys and quotes.

data cabling,network cabling,cat6 cable .

PVC Sleeves And Insulation on Fiber-Optic Cable

14 Oct 2014

PVC data cabling,network cabling,cat6 cable .pvc-sleeve- is a common plastic materials for different many uses and applications. PVC is flexible, cost-effective and hard-wearing. Plasticized PVC is considered on of the most popular materials not only for electrical insulation but also for data and fiber optic cables too.


PVC is Polyvinyl chloride. It can be bent and turned many times without cracking or warping. This safety feature makes it appropriate for multiple applications. The infusion of plasticizers provides the needed softness for the insulation and covering of electrical and data wires. Cable wire manufacturers can configure different thicknesses

Read More

Network Cabling Data Cabling

VoIP Solutions Business Start-ups and Corporations

29 Sep 2014

 Network Cabling Data CablingVoice over Internet Protocol (VoIP) is an innovative advancement of phone service. The technology has transformed traditional telephone service and introduced features that has recently included voice mail, caller ID, call forwarding, and call waiting. With virtual PBX, you can now call using broadband internet without spending a lot. Moreover, the need to make long distance calls is eliminated. Voice over Internet Protocol has features much like conventional telephone systems. However, there are more sophisticated elements like the conference call component and directory for employee extension numbers.


Why is Business VoIP Practical?


Business VoIP translates

Read More

Network Cabling, Data Cabling

Choosing Plenum Cables for Plenum Space

5 Sep 2014

Office Cabling Network Cabling, New York City The plenum space is described as that section of the building that makes possible air movement for HVAC systems. It also provides the space for conduits of heated, conditioned and return air circulation. The distance between the structural ceiling and dropped ceiling tiles is regarded as the plenum space.


The plenum space houses communication cables for telephone and computer networks. However, increasing neglect of cables in plenum areas create a major risk in case of fire.

Read More

Cat6, Network Cabling, Data Cabling

Upgrading To Cat6 Cable

26 Jul 2014

Upgrading to Cat6 Cable: Requirements for a Corporate Office


Cat6 , Network Cabling, Data Cabling

Technology continues to evolve and adapt to corporate requirements. Data volume has increased significantly and processing capacity demands faster access. IT managers have predicted that data production will be 44 times larger five years from now. And enterprises have to process and protect that data. Moreover, the amount of data in your business network system grows constantly.


Until recently, this was accomplished using the Cat5 cable. However, limitations is now causing some problems because it has a maximum data rate

Read More

Network Cabling, Data Cabling,basket type cable tray

Basket Trays

3 Jul 2014

 Network Cabling, Data Cabling,basket type cable trayThe basket type of cable tray is made from wire lattice. The tray provides a foundation for data cables and it facilitates cable management since wires are mounted along and inside the tray. Data cabling is generally smaller but heavier than electrical wires because they are bundled and carried by these trays. A solid steel tray is preferred if heavier cables will be installed but steel is more vulnerable to rusting and exposure to elements. On the other hand, basket trays are lighter than solid racks.


The basket makes cable management and distribution less complicated

Read More

Network Cabling, Data Cabling , cable tray

Uses And Benefits Of Cable Trays

25 Jun 2014

 Network Cabling, Data Cabling, cable traysThe cable tray is meant to prop up insulated cables for communication and power distribution. Cables are mounted on the tray, rather than placed inside a pipe. It can be likened to the structural cog of the building’s electrical layout, as it protects the cables both inside and outside. Wires are organized properly so wire maintenance is easier.


A cable tray facilitates the process of tracking down where wires come from for repairs, and also creates effective fire sealing between wall panels.

Read More