What is “Structured Cabling”?

27 Dec 2012

data cabling,structured network cables Traditionally computer network designers developed their systems with the assumption that they will operate on a specific type of cable using a specific type of connector. Thus, each manufacturer has its own cable and connector "standard," but that standard was for their own system only. For example, here are some “standard” cable/connector systems in use:

Read More

Cat5e, Cat6/6a Cabling ,Structured Cabling

Do Not Use Basket Tray against a Tight Ceiling

8 Aug 2012

When a new office design is in its initial stages, it is critical to consider proper handling of utilities, power water and cabling inside the walls and ceiling. For cabling, it is necessary to use hooks to hold the cables above the drop ceiling. When the installation of cable involves large numbers of cables traversing lengthy expanses, it is normal to install cable ladder trays up in the ceiling to carry the bulk of the cable along the main corridors of the office. Cable ladders vary in quality and cable handling capabilities. The amount of cable and the budget of the project will determine the type of cable ladder that will be built.


A higher quality cable ladder will, in the long run, save time and money during the installation phase of a cabling project. The alternative to a cable tray is to install cable conduit. Considerations in choosing to use a cable ladder tray system include the following:

Read More

Data Cabling, Cat5e, Cat6/6a Cabling

US Court of Appeals Veterans Affairs – Cabling Project Notes

18 Jun 2012

Project Objectives (Do not call, this project has been COMPLETED)




Number of Drops: 360 (140 duals, and 20 quads)

Ceiling: Non-plenum, separate ducting

Racks: Enclosed, 19”, will already be installed by customer

Switches: Provided by customer, 48 port

Patch cables: None necessary. They will provide patch cables from wall plate to computers and from patch panels to switches.

Labeling and documentation of all cabling is important. How this looks is important to them. Please provide a spreadsheet of all wallplates and rooms.

  • Location is behind elevators.

  • All workstation runs will terminate in wiring closet behind elevators.

  • We will mount patch panels in this closet on the wall. Use 24port, Cat5e, patch panels.

  • They will mount racks for switches.

  • 4 pairs of fiber will run from the closet to the server room on the same floor. We are to provide the cabling plant for the fiber.

















Office Cabling Network Cabling

Server Room:




  • 2, 24 port patch panels per rack.

  • Cabling plant for fiber to switch closet.


Existing server room


Click HereThey want cable management hardware to be part of the solution. What you see in this room is what they’re cleaning up and looking to make high end and professional in the new location. Photos here include existing fiber. Note the ceiling cable management rack. In the new location these will be in place in the server room and along the ceiling in the main hallways.












New server space - Roughed in area they’re moving to.




 

 

 

 

 

 

 

 


General Floor Space:



  • Quad drops in each office and cube in the technology area

  • Dual drops in all other offices

  • 6 drops for cable t.v.

  • Wall facing outside is already dry walled and insulated


Part of that wall has large window with wall space under it. Customer is unsure if drops will go there or anywhere along that outside wall.

Includes the outside wall. They’re not sure if there will be drops along this wall. If so it’ll be interesting because of the insulation. Also note that they MAY want drops under the windows along this wall.

There are some pictures of the ceiling details. Also note that the client will already have cabling runners ceiling mounted down the middle of the two main hallways to the server room.



























Special Fiber Optic Line Item Bid:


US Court of Appeals wants this as a line item so they can choose to add this work or not when they’re doing the budget.

Fiber runs between floors. The floor plan represents the 6th floor. 14 runs broken out as follows. A single 6-strand fiber cable will be run from the 6th to each floor in the table below. Three strands will be connected and three will be left as spares.



























# of Runs Floor
3 11th
3 10th
3 9th
3 2nd
2 Mezzanine

12’ ceilings, concrete floors.

Conduit already exists between the floors. We have to repack the conduit we use with fire stop putty to meet fire code. See photos of the “Switch closet” for conduit images.