Network Cabling ,Data Cabling,CAT2 6A UTP

Issues to Avoid with Cat6a Cables

22 Dec 2014
Network Cabling ,Data Cabling,CAT2 6A UTPA newly popularized cable is Cat6a. It is the new “cable on the block” which has prolonged the life of copper cabling. Cat6a has the shielded twisted and untwisted pairs with different advantages and features. It supports Gigabit Ethernet up to a hundred meters. However, you need to understand and cope with several issues.

Contentions


The size of Cat6a cable is larger than Cat5e. Copper is inherently unreliable due to Bit Error Rates or BER. This is why manufacturers have designed Cat6a cables with a smaller cross-section. It takes up less space in the tray. Yet, this space is needed to minimize crosstalk between cabling pairs. The protective shield in Cat6a cable adds to the expense.

Electricity and Mechanical Facets


Aside from the electrical issues, Cat6a Untwisted Pair (UTP) is fabricated with bigger conductors. It has more rigid twists compared to Cat5e and Cat6 and these heavier conductors plus large and stiffer jacket combines to make for more difficult cable installation. Besides, the external diameter of the UTP means that the Cat6a cable takes up more room in the trays and conduits.

Electrical and mechanical issues should not be overlooked since this can affect performance. The physical stability of Cat6a is essential to its transmission performance. Cat6a can be more sensitive to degradation of signal compared to Cat5.

These may be produced by the following:



  • Cable twisting generates signal reflection.

  • Excess insertion pressure on cables can cause poor connector performance.

  • Weakness of RJ45 (communications) connectors.


For example, if the cable is wedged in a door or compressed or squeezed by a heavy object, can result in sporadic network problems which may not be easy to detect. Nevertheless, Cat6a functions at enhanced specifications compared to Cat6 UTP. Considering all of these issues it may seem that fiber cable will become the ultimate future for 10 Gigabit Ethernet. It is up to users and the market forces to make the choice.
IT Support,Data Cabling,Atlanta GA

Advantages Of Using Cat6 Cables

22 May 2014

Cat 6Category 6 or Cat 6 network copper cabling is the preferred infrastructure for Ethernet, Fast Ethernet, and Gigabit Ethernet. It has a maximum performance of 250 MHz, or 500 MHz for the more contemporary Cat6a standard. This type of cabling may be utilized for a maximum distance (end to end) of 100 meters, or 55 meters for the 10 GBASE-T networks. Aside from support for higher performance, Cat6 includes more rigid specifications for crosstalk and system noise. Although Cat6 is anticipated to surpass Cat 5 and Cat 5e cabling soon, all three cable varieties are still widely used for network installations.



Fast and Credible Performance


Most IT experts recognize this type of copper cabling for its speedy network performance due to its ability to deliver gigabit data transmission speeds. It has a parallel structure similar to Cat5 and Cat5e. These copper cables have eight wires coiled as one to form four pairs. The major difference is that one pair of the Cat 6 cable wires does not touch the others, so it can produce twice the transmission capacity of the two other models.


It is also backward compatible. The plug and port of Cat6 cable is the same as the 5 and 5e models. Thus, it can be plugged into any outlet that supports these cables. For instance, you can use the Cat 5 connection for a Cat 6 cable although it will not produce the full speed of the Cat 6 cable.



Resistance to Heat and Flexibility


Copper cables are second to silver in terms of effective conductivity, but among non-precious metals, these wires can cope with a broader load of electricity with less need for insulation. Furthermore, copper cabling has more resistance to heat, which eliminates overloading problems. They are impervious to corrosion despite their shiny surface. Copper is also more pliable, so it can be twisted without the risk of splitting. In fact, copper is used in fabricating thick wires for applications where very thin wires are required. It can also be part of an upgrade if you are looking forward to a more optimal network. Copper Cat5, Cat5e and Cat6 are the industry standards for most small to medium sized offices.


There are certain problems that deserve consideration. Such as copper cabling failure in high-performance wiring systems. Users may also need to contend with poor component performance, such as bad cable segments or connectors that do not comply with specifications. However, these problems are frequently the result of human error. So the choice of copper cabling is  still a good one.