How Improper Cabling Causes Network Issues – Part 1

5 Sep 2018

Data Cabling Structured Cabling Washington DCYour employees are dissatisfied by their company’s network performance, and it is affecting their productivity. A number of factors must be taken into consideration. How many users are attempting to use resources simultaneously? Have you taken into account how much the use of devices has grown? Is your network equipment sufficient to meet demand? Answering the above questions will help, but network issues may be directly related to your company’s structured cabling.



Outdated Cabling


In many instances, the age of your structured cabling system may be responsible for poor network performance. 15-year-old cabling may have met standards when it was installed, but now it may be unable to handle the ever increasing network traffic needs of your company.


An internet service provider (ISP) provides the cable that provides the connection from your company’s network to the internet. When this backbone component fails to meet today’s bandwidth standards, bottlenecks may occur.


In situations where you are attempting to operate at speeds that are too high or carry excessive bandwidth via a cable that not rated for the capacity, it will be noticeable to users and their productivity will decline, hampering business operations.



Quality of Cabling


Cabling manufacturers rate their cables in terms of capability and performance. For example, CAT6 and CAT6a cabling have different capabilities, CAT being an abbreviation for category. A manufacturer must meet the performance standards set by the Telecommunications Industry Association (TIA) for each category of cabling.


Cabling that exceeds minimum standards will attain higher network speeds without having to upgrade your cabling. In contrast, for cabling that only meets the minimum standards, the company network speed will be unable to expand much beyond the rating of the cable.


It is helpful to understand cable standards and ratings. Even though a cable is labeled Category 6A, it is not automatic that it meets the minimum performance standards of this category. The brand name and manufacturing quality will play a big role in the cable’s output.


Part 2 will discuss Compatibility, Patch Cords, and Poor Installation.



Progressive Office Cabling


Founded in 1986, Progressive Office’s success has been a direct result of years of commitment to seeking solutions on behalf of our clients in the Washington, D.C., Atlanta, Pittsburgh and New York City areas. Efficiently working together, Progressive teams get cabling installed and operating as fast as possible while minimizing disruption and downtime. Call our toll free number (800) 614-4560 today.


;
cabling, network cabling,Washington DC

Top Ten Tips for Business Data Cabling – Part 2

22 Aug 2018

cabling, network cabling,Washington DCAs discussed in Part 1, business cabling projects can be a challenge to properly design, install, and accomplish on schedule. The key to success is finding an experienced team that will provide structured cabling services of high quality. Part 2 will discuss Maintaining Standards, Planning Well, Respecting Regulations, Staying Up-to-Date, and Testing Infrastructure.



Maintaining Standards


Maintain the established standards and best practices of structured cabling. Neglecting to do so will probably reduce quality and the efficiency of a data network. For guidance, refer to the standards set forth by the Telecommunications Industry Association.



Planning Well


Planning well will help future proof your organization. Do your best in estimating what your company will need for the next five years. CAT5E is now the standard, and it can support a maximum of 1000 Mbps. If your company needs more bandwidth, CAT6 is rated at a maximum of 10 Gbps. Re-cabling soon after installation will be disruptive and expensive.



Respecting Regulations


Compliance with codes, laws, and ordinances typically protects the lives of employees and first responders. A company found to be violating regulations will be fined and required to rewire the cabling so it is up to code. In the event of injury or death that is attributable to a violation, individuals found responsible may be held financially and perhaps criminally liable.



Staying Up-to-Date


Staying current with technological developments and regulations related to structured cabling and IT infrastructure will allow you to provide guidance to your company that has foresight. Knowledge of trends will let you anticipate what your IT infrastructure will need in the future.



Testing Infrastructure


Testing IT infrastructure during the installation of cabling is good practice. For efficiency, tests should be performed in phases to detect and fix problems quickly. Testing only after the installation of hundreds of feet of cabling will discover issues far too late and result in time wasteful revisions, repair, or replacements.



Progressive Office Cabling


Founded in 1986, Progressive Office’s success has been a direct result of years of commitment to seeking solutions on behalf of our clients in the Washington, D.C. and New York City areas. Efficiently working together, Progressive teams get cabling installed and operating as fast as possible while minimizing disruption and downtime. Call our toll free number (800) 614-4560 today.

Network Cabling,Cat6 Cable New York City

Basics and Benefits of Zone Cabling – Part 2

14 Dec 2017

Network Cabling,Cat6 Cable New York City As mentioned in Part 1, zone cabling designs provide benefits in materials savings, decreased installation times, and easier MACs (moves, adds, and changes). Part 2 will continue discussing the basics and benefits of zone cabling.



Designs


Experts recommend CAT 5e and 6 UTP (unshielded twisted pair) zone cabling topology with a connecting block system within the ZE (zone enclosure). This configuration will render unnecessary the stocking of factory pre-terminated and tested interconnect cords for connections in the ZE, simplifying cable management through the elimination of cable slack.


Please note that CAT 6A UTP media is not recommended for zone cabling due to reasons involving performance and flexibility. UTP cabling is vulnerable to crosstalk in particular installation scenarios. In addition, it is not the best media for supporting remote power applications with loads of 30W or more. Because CAT 6A UTP zone deployment is dependent on modular connections inside the ZE, connections provided by pre-terminated and tested interconnect cords need to be available for rapidly enabling MACs. Affordable shielded zone cabling solutions are recommended to address these situations.



Cost Savings


Even though more CAPEX (capital expenditure) will be necessary for a zone cabling installation, assessing total costs should also account for OPEX (operating expenditure). The performance of MACs is classified as OPEX, and studies by Siemon found there are hundreds of dollars in savings from each move, addition, or change when using a zone cabling design versus a traditional cabling design. Their study also discovered a tipping point when ROI begins accruing from utilizing a zone cabling design.


IT (information technology) needs for many organizations evolve constantly, which requires being able to quickly reconfigure floor space. An improved capability of supporting MACs will allow owners of facilities to achieve considerable ROI benefits from deploying zone cabling systems in a two to five year period. According to Siemon, the combined costs of CAPEX and OPEX for zone cabling designs will be invariably less than traditional cabling designs


Part 3 will continue discussing the basics and benefits of zone cabling.



Progressive Office Cabling


Founded in 1986, Progressive Office’s success has been a direct result of years of commitment to seeking solutions on behalf of our clients in the Washington, D.C. and New York City areas. Efficiently working together, Progressive teams get cabling installed and operating as fast as possible while minimizing disruption and downtime. Call our toll free number (800) 614-4560 today.

Network Cabling, Network , Structured cabling, cable, Washington DC

8 Network Cabling Mistakes to Avoid – Part 2

14 Nov 2017

As discussed in Part 1, the improper I can result in poor network performance, maintenance issues, and concealed expenses. Part 2 will discuss four more network cabling errors to avoid. Remember to consult with a cabling company that is experienced and provides excellent service.



Mistake No. 5: Ignoring Distance Limitations


The standard distance limitation for UTP cabling with Ethernet at 1 Gbps is 100 meters. For cabling used for 10 Gbps or 40 Gbps, it is important to be aware of the distance limitations of the kind of cabling that will be used. Let’s say your project plans to run 10 Gbps for a maximum of 100 meters over UTP cabling. This will require utilizing at least CAT 6A cabling.



Mistake No. 6: Bypassing Codes


Bypassing local codes may result in endangering first responders. In most facilities, it is prohibited to use PVC-jacketed cabling within air handling spaces. When PVC cabling burns, it produces poisonous fumes that can be hazardous to firefighters and other first responders who must enter the facility during an emergency.


The failure to comply with local codes with respect to low voltage cabling may result in costly fines and perhaps even being ordered to completely remove and reinstall cabling, an expensive exercise. Working with a reputable cabling service company that is knowledgeable regarding local ordinances will avoid future problems.



Mistake No. 7: Neglecting Testing


After cabling is installed, testing should be performed on every cable, using equipment that can verify functionality. The verification of cable lengths and specifications is also important. For certain transmission rates, it must be verified that the cabling is capable of adequately providing support.



Mistake No. 8: Non-Compliance with Standards


Your company’s project should comply with technical standards to ensure the proper functioning of its network. Non-compliance will make noise and interference more likely, leading to inefficiency and poor network performance.


Network cabling standards are used worldwide and are drafted by ISO/IEC, CENELEC and the Telecommunications Industry Association (TIA). TIA (USA) issues the ANSI/TIA-568 standards for telecommunications cabling in commercial facilities.



Progressive Office Cabling


Founded in 1986, Progressive Office’s success has been a direct result of years of commitment to seeking solutions on behalf of our clients in the Washington, D.C. and New York City areas. Efficiently working together, Progressive teams get cabling installed and operating as fast as possible while minimizing disruption and downtime. Call our toll free number (800) 614-4560 today.

IT Support,Data Cabling,Atlanta GA

Why Structured Cabling is Important for Business Phones

27 Sep 2017

IT Support, Data Cabling,Atlanta GAIf your organization is considering a new VOIP (Voice Over Internet Protocol) system, you should think about the structured cabling system needed to support it and maximize its potential. The following summarizes the advantages your digital phone system will have with a well-designed structured cabling system.



Decreased Noise


CAT 6 and CAT 6A cable provides more noise reduction than older cables. Fiber optic cabling is even better. Less noise resistance results in more static and faulty connections during phone conversations. Higher levels of noise also decrease network speed because the system is forced to retransmit data until it is no longer corrupted. Although purchasing lower quality cable saves money in the short run, it may result in long term business losses because of slower response times and annoyed customers.



Lengthened Runs


Higher quality cable will be capable of supporting longer runs that are free of artifacts and errors. Fiber optic cables are not restricted by the length of runs. It is the superior option for a data center or business telephone system because of its excellent noise resistance and high speed. Although second choices, CAT 5e to CAT 6A cabling are capable of supporting runs to 100 meters without noise. Cables that can support long runs provide greater flexibility for layouts, decreasing the need for data hubs or repeaters and increasing reliability.



Maintenance Savings


CAT 5e, CAT 6, and fiber optic cables are highly dependable. However, if they ever become faulty or the network needs to be reconfigured, a structured cabling system that is well organized and diligently marked will save time spent on maintenance. While a company’s network is down, business may be impacted, resulting in lost revenue. Tracing faults is made much easier by a sound structured cabling system.



Transmission Speed


Business is often time-sensitive, and you will want to use the highest quality cable your company can afford. CAT 6A cable is capable of supporting a maximum of 10 Gigabits per second while CAT 5e can only achieve 100 mbps. Older, less capable cables are not recommended because their slow data transmission and high noise levels cannot meet current VOIP demands.



Progressive Office Cabling


Founded in 1986, Progressive Office’s success has been a direct result of years of commitment to seeking solutions on behalf of their clients in the Washington, D.C. and New York City areas. Efficiently working together, their teams get cabling installed and operating as fast as possible while minimizing disruption and downtime. Call their toll free number (800) 614-4560 today.

Data Cabling, Cat5e Cat6/6a Cabling, Washington DC

New Standards for Cabling and Category 8 Update

20 May 2017

Data Cabling, Cat5e Cat6/6a Cabling, Washington DCThe selection of proper cabling has become more crucial and also more complicated, but the process can be made easier by knowing about the choices available and updates regarding the development of Category 8 (CAT 8).


There are several organizations that determine the standards for cabling, such as the ISO (International Organization for Standardization), IEC (International Electrotechnical Commission), TIA (Telecommunications Industry Association), and CENELEC (European Committee for Electrotechnical Standardization). However, our discussion will primarily focus on ISO/IEC and TIA.


As its standard calls for 10Gb/s rates of transmission, 10GBASE-T cabling is the fastest in the market. Unable to support 10Gb/s, Category 5e does not receive 10GBASE-T standard recognition.  In addition, advisories by the TIA and ISO/IEC and TIA state that new class E/category 6 cabling should not be installed to support 10GBASE T. As a result, the cabling options for new installations that meet the 10GBASE-T standards for carrying data up to 100 meters are only found in the class EA/CAT 6A, class F/CAT 7, or class FA/CAT 7A.


Regarding data centers that are newly built, ISO, along with other standards organizations, have determined that CAT 6A should be the minimum grade. The task force overseeing IEEE 802.3 40GBASE-T have drafted the baseline objectives for the future 40 Gb/s standard, which is well beyond the capabilities of CAT 6A.


Cabling of a higher category traditionally matches and surpasses the electrical and mechanical standards of what preceded it. In addition, it is backwards compatible. Although TIA calls for cabling systems to perform at CAT 6A minimum, it will not be adopting CAT 7 or 7A as determined by ISO/IEC. TIA is naming its next class of cabling, Category 8, to differentiate it from ISO/IEC standards for CAT 7 and CAT 7A.


Interestingly, the proposed performance for CAT 8 will not be meeting or exceeding CAT 7A standards for up to 1 GHz. For example, regarding parameters for internal crosstalk, CAT 7A is superior to CAT 8 by more than 20 decibels.



Union Network Cabling


When work requires a unionized cabling group, call on Progressive Office Inc. for your commercial Cat5e/6/6a and fiber cabling projects. Specializing in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290

CAT 6a,network cabling, DC

Gradual Phase Out of CAT5e Cabling in Office Buildings

13 Mar 2017

Class E (CAT6), Network Cabling, DCAfter their Milan working group meeting in 2015 regarding cabling standards, the International Organisation for Standardisation (ISO) and International Electrotechnical Commission (IEC), together known as the ISO/IEC, made the announcement that Category 5e (CAT5e) cabling will be considered obsolete for new installations in commercial and industrial buildings.


Setting the first international standard for cabling more than 20 years ago, ISO/IEC continually works on the development, maintenance, and promotion of technology and communications technical standards. A major change for the cabling of office buildings is now being implemented worldwide, raising the minimum horizontal cabling requirement from Class D (CAT5e) to Class E (CAT6), along with recommendations for installing Class EA (CAT6a) or faster cabling. Essentially, this will result in making CAT6 the minimum requirement for installations in new office building installations.


Providing a maximum performance of 100 MHz over computer networks, CAT5e has been utilized in structured cabling for both Ethernet and IP communications.  Considered adequate for fast Ethernet and gigabit Ethernet, CAT5e has the additional capability of carry video and telephony signals. The original ISO/IEC 11801 standard now has cabling classes that were added for enabling the support of up to 10 gigabits a second, such as CAT6, CAT6A, CAT7 and CAT7A.


CAT5 is not capable of matching the speed of data that CAT6 or CAT7 cabling can deliver. CAT6 has a maximum performance of 250 MHz, while CAT7 has a maximum performance of 600 MHz, enabling ultra-fast Ethernet. In addition, CAT7 features better durability and a longer service life than either CAT5 or CAT6 cabling.


More than 20 years have passed since ISO/IEC 11801 made its debut as an international standard, and it has led the way for the reliable implementation of data and voice cabling globally. However, CAT5e is now in the process of being phased out. Superior classes of cabling are being installed at new office buildings. Wireless LAN infrastructure is upgrading at a rapid pace, along with its speed, to keep up with the growing number of smartphones, laptops, and tablets. These demands have forced the gradual replacement of CAT5e with newer cabling that will meet current and future user expectations for fast and efficient data capability.



Union Network Cabling


When union work requires a unionized cabling group, contact Union Network Cabling for your commercial Cat5e/6/6a and fiber cabling projects. They specialize and excel in cabling for data, voice, security, and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290

Network Cabling,data cabling,,DC

Comparing Cat 7 to the Other Cats

3 Mar 2017

Data cabling, network cablingNowadays offices and homes utilize either a wireless (Wi-Fi) connection or wired network connection. Usually faster than Wi-Fi, wired connections also have lower latency. These two types of network connection continue to progress technologically, providing users ever increasing speeds.


In the case of home networks, the speed of the internet connection is typically the issue, and the cabling may not be a factor. However, a company must consider the specifications of particular cables and how these would meet its requirements in order to properly decide which to select. There can be a vast difference between the network speeds of the various Ethernet cables.



Types


Cables are differentiated by standard categories. Category has been abbreviated to “Cat” by the industry. Currently, the most common cables in use are Cat 5, Cat 5e, Cat 6, and Cat 6a. The newest type is Cat 7. Every type is backward compatible, allowing users to insert a newer cable into a device that was manufactured for an older cable without any compatibility issues arising.

Progress


With every new cable category, users were provided increased speed and decreased crosstalk. Newer category cables provided faster speeds at increased lengths of cable. The following offers comparisons at 100 meters of cable, illustrating the differences between the ethernet cable categories:

Cat 5 - Considered slow and inadequate for business networks, providing up to 100 Mb/second at 100 Mhz.

Cat 5e - provides up to 1 Gb/second internet speed at 100 Mhz.

Cat 6 -provides up to 1 Gb/second, and cable lengths up to 55 meters can give internet speeds of 10 Gb/second at 250

Cat 6a -can provides speeds up to 10 Gb/second, to 100 meters of cable length, at 500 Mhz.

Cat 7 - provides speeds up to 10 Gb/second to 100 meters of cable, at 600 Mhz.

History


Cat 5 was the standard in 1995, Cat 5e became standard in 2001, and Cat 6 was introduced in 2002. Arriving in 2008, Cat 6a is typically the newest cable the majority of companies have used because it is not considered necessary to update to Cat 7 yet. Cat 7a and Cat 8, which were respectively released in 2010 and 2013, are still waiting in the wings.

Union Network Cabling


When union work requires a unionized cabling group, call on Union Network Cabling for your commercial Cat5e/6/6a and fiber cabling projects. We specialize in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290
Cat5e Cat6/6a Cabling,cable installations

What is Certification and is it really necessary?

10 Aug 2015

Environmental Problems with Cat5e, Cat6, and Cat6A Cable


Cable must be installed so that external environmental factors do not have an effect on the performance of the network. Problems can occur at the patch panel punch down, at the wall plate jack and anywhere along the cable itself. Maybe an inadvertent kink is in the cable. Or there is a snag in the cable as it got pulled across a rough surface in the rafters above the drop ceiling. Or maybe the cable got too close to an electric line. Any one of these issues can degrade the performance of an individual cable.


There are two basic kinds of testing that is performed during the installation of cabling:




  1. Continuity Testing

  2. Certification


Continuity Testing



Continuity Testing is a test to insure that the wires in the connectors at the faceplate and at the patch panel are connected up correctly. There are 4 pairs of wires and each wire is color-coded. So, as the technician is connecting everything, a particular sequence is required. If a wire is connected in the wrong order, the cable will fail. This is a basic wire-mapping test. If this test fails, the connector and wires are re-examined and re-terminated. All of our cable installations include continuity testing.


But the only way to insure and guarantee full speed to every cable is to do Certification Testing on each cable.



Certification



Certification Testing is a performance test that utilizes a precision device that sends a signal from one end of the cable to the other. This test is the only way to test the data-carrying capacity of each cable. For example, Cat6A cable is rated to run at 10G/sec. But if you have an issue, the cable will work but it might be running at a slower speed. It passes the continuity test but it's not performing at 100%. Certification will find the fault, pin-pointed to its exact location so that our technician can fix it, retest it and fully certify it as 100% top-speed rated.


The Fluke DSX-5000 is a very expensive test device that we employ to test and certify our cabling jobs. It costs about an extra $10 per cable to get everything tested and certified. But without this test, we can't guarantee top speeds throughout your network. And, considering that most cabling projects have a useful lifespan of 15 - 20 years, this investment upfront is very cost-effective. It means you will have full speed to every device for the entire lifetime of your cabling infrastructure.


Certification includes a PDF report showing every cable and the test results.


Do you have an upcoming cabling project?