Structured cabling,Network Cabling, Washinton DC

Data Center Cabling Best Practices – Part 3

5 Jun 2017

cable management,Network Cabling,New York CityAs mentioned previously, modern data centers must be flexible, scalable, reliable, and manageable, making best practices required. Part 3 will cover Color Identification and Naming Scheme.



Color Identification


A method of fast visual identification, color coding makes management simpler, conserving time spent on the tracing of cables. Patch panel ports can also be coded, and various colored jacks and inserts are also coded. As determined by a particular manufacturer’s own color scheme, cables are available in numerous colors, each of which can be made applicable to the specific function of a cable or connection type.


Color schemes are expandable through the use of color bands at the end of every cable, using various colored sleeves and colored ports on the patch panel. However, it will also be necessary to use a secondary non-color scheme to make it possible for those who are color blind to identify the cables.



Naming Schemes


After determining the physical layout for the cabling that will be used, use a naming scheme that can be logically applied for facilitating fast and effortless identification of every cable component. Labeling can be an especially effective way to improve team communication among staff members because it makes confusion and uncertainty unlikely when a colleague must search for a particular component. Clear labeling is integral to the success of the naming scheme, and it should not be neglected.


A good naming scheme documents and labels every cable component. The following is the typical hierarchy for a naming scheme: Building, Room, Rack, Patch Panel, Workstation Outlet, Port, and Cable. Each should receive a designation indicating its location preceded by the area(s) above it. For example, Rack A03 would receive the designation SJ01-5D11-A03, if Room is designated SJ01-5D11, and Building is designated SJ01.


Upon the approval of the naming scheme, your team can begin labeling components. The team should prioritize drafting a manual that details the naming scheme and include it as part of the training program for newly hired data center administrators.


The Best Practices for Cable Component Selection will be discussed in the next series.



Union Network Cabling


When your work requires a unionized cabling group, call on Progressive Office Inc. for your commercial Cat5e/6/6a and fiber cabling projects. Specializing in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290

IT Support,Data Cabling,Atlanta GA

The Organizations that Set Cabling Standards

27 May 2017

Data Cabling,Network Cabling,Atlanta GAThe TIA (Telecommunications Industry Association) and the ISO (International Organization for Standardization) are the primary organizations that oversee the development of structured cabling standards for the industry. Committees formed by the IEEE (Institute of Electrical and Electronics Engineers) provide assistance through testing and setting performance specifications for various standards.


Compliance with standards ensures the functioning of systems at specified levels, backward compatibility, and a greater selection of equipment will exist. General global recognition of standards permit utilizing equipment sourced from various countries inside computer systems. Requirements for the components of optical and copper cabling including cables, assemblies, connectors, cabling spacing and pathways, administration, field testing, and installation are standardized to make worldwide acceptance possible.


Technicians in North America typically use TIA standards, while the rest of the world uses ISO standards. Examples of organizations that set regional and national standards organizations are CENELEC (European Committee for Electrotechnical Standardization), CSA (Canadian Standards Association) and JSA (Japanese Standards Association). Their standards are generally compatible with TIA and ISO.


Different terminology used by TIA and ISO Associations sometimes cause confusion because they refer to the same item. For example, what the TIA terms as Cat5e is what ISO terms to be Class D. However, adherence to standards set by TIA and ISO ensure system cabling requirements are properly implemented in the categories below.




  • Insertion Loss – Decrease of signal strength down the transmission line.

  • Return Loss – Measurement of signal reflections on the cable.

  • NEXT – Near End Crosstalk Loss due to signal coupling.

  • Propagation Delay / Delay Skew – Elapsed time for signal to reach other end of cable or the delay between signal arrival at far end on slowest and fastest cable pairs.

  • ACR – Difference between insertion loss and NEXT.

  • ELFEXT – Identical to NEXT, but for cabling system’s far end.

  • PSANEXT / PSAACRF – Power sum alien crosstalk at near end / Power sum alien crosstalk at far end.


Due to ever-increasing data rates, the efforts of the standards organizations are assuming greater importance in terms of ensuring proper system design.



Union Network Cabling


When your work requires a unionized cabling group, call on  Progressive Office Inc. for your commercial Cat5e/6/6a and fiber cabling projects. Specializing in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290

Data Cabling, Cat5e Cat6/6a Cabling, Washington DC

New Standards for Cabling and Category 8 Update

20 May 2017

Data Cabling, Cat5e Cat6/6a Cabling, Washington DCThe selection of proper cabling has become more crucial and also more complicated, but the process can be made easier by knowing about the choices available and updates regarding the development of Category 8 (CAT 8).


There are several organizations that determine the standards for cabling, such as the ISO (International Organization for Standardization), IEC (International Electrotechnical Commission), TIA (Telecommunications Industry Association), and CENELEC (European Committee for Electrotechnical Standardization). However, our discussion will primarily focus on ISO/IEC and TIA.


As its standard calls for 10Gb/s rates of transmission, 10GBASE-T cabling is the fastest in the market. Unable to support 10Gb/s, Category 5e does not receive 10GBASE-T standard recognition.  In addition, advisories by the TIA and ISO/IEC and TIA state that new class E/category 6 cabling should not be installed to support 10GBASE T. As a result, the cabling options for new installations that meet the 10GBASE-T standards for carrying data up to 100 meters are only found in the class EA/CAT 6A, class F/CAT 7, or class FA/CAT 7A.


Regarding data centers that are newly built, ISO, along with other standards organizations, have determined that CAT 6A should be the minimum grade. The task force overseeing IEEE 802.3 40GBASE-T have drafted the baseline objectives for the future 40 Gb/s standard, which is well beyond the capabilities of CAT 6A.


Cabling of a higher category traditionally matches and surpasses the electrical and mechanical standards of what preceded it. In addition, it is backwards compatible. Although TIA calls for cabling systems to perform at CAT 6A minimum, it will not be adopting CAT 7 or 7A as determined by ISO/IEC. TIA is naming its next class of cabling, Category 8, to differentiate it from ISO/IEC standards for CAT 7 and CAT 7A.


Interestingly, the proposed performance for CAT 8 will not be meeting or exceeding CAT 7A standards for up to 1 GHz. For example, regarding parameters for internal crosstalk, CAT 7A is superior to CAT 8 by more than 20 decibels.



Union Network Cabling


When work requires a unionized cabling group, call on Progressive Office Inc. for your commercial Cat5e/6/6a and fiber cabling projects. Specializing in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290

Structured Cabling, Cabling, Washington DC

Data Center Cabling Best Practices – Part 1

4 May 2017

Structured Cabling, Washington DC, New York CityModern data centers are equipped with devices and networking equipment that connect them. These devices demand increasingly greater bandwidth, and so their fiber or copper cabling must perform at a high level. Today’s data centers must be flexible, scalable, reliable, and manageable, making best practices required.



Planning the Infrastructure


Thus, documenting the existing and planned network, along with its equipment is needed. A flexible patching structure will permit the interconnection of devices at desired locations.



Structured Cabling


The structured approach of cabling revolves around the design of runs and connections that ease cable identification, maintenance, repair, and future expansion or reconfiguration. A Main Distribution Area (MDA) and Horizontal Distribution Area(s) (HDAs), along with two-post racks that permit improved access and cable management, will be needed.


MDA and HDA components must be of high quality and capable of bearing expected future loads. Their layout should have horizontal and vertical cable managers. The MDA contains primary cross-connects and core networking equipment. The HDA contains the cross-connects for the distribution of cables to Equipment Distribution Areas (EDAs). Patch cables will connect servers and storage by utilizing patch panels at their respective EDA.


Next, the equipment racks inside the data center must have their layout determined. A horizontal cabling configuration will be used for the distribution of cables from the HDA to the EDA. Flexible connectivity is required by a dynamic data center environment. The goal is the implementation of a system that transmits fiber channel, Ethernet, and other protocols.


Future port and application requirements will also need to be considered. Expansion and technological advances must be anticipated, so the installation of ports and cabling needed in the future should be done now to save on labor costs and downtime if upgrades are needed.



Structured Infrastructure Benefits



  • Cable identification and fault isolation simplified

  • Consistent cabling lays sound foundation for future

  • Future expansions and modifications made easier

  • Standard-compliant components from multiple vendors possible

  • Flexible connections provided


Cabling for Modular Data and High Density/High Port Count Fiber Equipment will be discussed in Part 2.



Union Network Cabling


When union work requires a unionized cabling group, call on Progressive Office Network Cabling for your commercial Cat5e/6/6a and fiber cabling projects. Specializing in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290

cable,Data Cabling ,Cat5e, Cat6/6a Cabling

Category 5e Cabling Becoming Obsolete

4 Apr 2017

cable,Data Cabling ,Cat5e, Cat6/6a CablingIt is inevitable that applications requiring speeds greater than 100 Mbps and 1000 Mbps will increase. The growing use of wireless devices, high resolution images, HD video streaming, surveillance, and multimedia are straining the capacity of Category 5e infrastructure, and there will come a point when it will be unable to cope.


Although it is capable of handling 1000 Mbps speeds at 100 MHz, the upgrading of Category 5e cabling will be necessary in the near future in order to support new applications and emerging technologies that will be deployed by businesses that are bandwidth intensive.



Category 5e Inadequate in Near Future


Cabling will be migrating from being behind walls to above ceilings, where it can end at a wireless access point (WAP). Much more cabling will be needed to serve an increasing utilization of WAPs for numerous users.


The advent and growth of new Wave 2 WiFi devices, which transmit at data at ranges of 1 Gbps up to perhaps 7 Gbps, will require faster Ethernet links for the connection of these WAPs. Installing Category 6A cabling may be the only effective solution for companies. The need for average speeds greater than 1G is increasing, perhaps to 10G. Category 5e is incapable of carrying speeds of 10 Gbps speeds over a required distance of 100 meters.


An emerging technology using balanced twisted-pair cabling, HDBaseT is used to transmit uncompressed HD video, audio, Ethernet, control, and power over 100 meters. Category 5e will be unable to support it, while Category 6A cabling is capable.


4-cable pair PoE, the next power over Ethernet standard, provides power more efficiently. However, the gauge of cable must grow in order for the reduction of resistance and permit higher power delivery. Consequently, 4-pair PoE has superior performance on Category 6A 23 AWG than Category 5e 24 AWG.



Cabling Standards Recommend Category 6A


For certain organizations, such as educational institutions, commercial buildings, data centers, and healthcare facilities, new installations require or recommend at least Category 6 cabling. Even though Category 6A may require greater capital expenditure than Category 5e cabling, costs will be decreased in the long term. A company’s network will be future proofed and will be capable of supporting new applications and emerging technologies.



Union Network Cabling


When union work requires a unionized cabling group, call on Union Network Cabling for your commercial Cat5e/6/6a and fiber cabling projects. Specializing in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290

Cable Management,Cable Management ,Data Cabling ,Cat5e, Cat6/6a Cabling

Overview of Cable Management Practices – Part 2

28 Mar 2017
Cable Management ,Data Cabling ,Cat5e, Cat6/6a Cabling

As mentioned in Part 1, the wired industry continues to grow despite the trend towards wireless communications during the past decade because of security concerns. Concrete trenching and floor decking were discussed as two of the four main practices of cable management. Part 2 will discuss Overhead Cabling/Cable Drops and Underfloor Cable Management. Consult with experienced professionals to make your cabling project a long-term success.



OVERHEAD CABLING/CABLE DROPS


Deployed within single-story and multi-story buildings, overhead cabling provides flexibility. This method uses overhead space, which can either be a dropped ceiling or an exposed ceiling. Cables and conduit are suspended from the ceiling, and cable drops, which are concealed by chaseways or poles, descend to serve work areas.



Advantages


This method does not require any cutting or trenching of concrete cutting. Unoccupied areas are used to install conduit and cabling.



Disadvantages


It will be a challenge to reroute cabling as technicians will need to use a ladder all along a line. Cable drops are generally considered an eyesore, and so this practice is highly discouraged for facilities that emphasize customer experience, such as retail. It may not be appropriate in the work areas of certain professions such as law offices.



UNDERFLOOR CABLE MANAGEMENT


Utilizing access flooring for the routing and concealment of cables, underfloor cable management may be the most advantageous. Cables can be routed beneath the flooring or within the floor itself in low-profile access flooring.



Advantages


Underfloor cable management does not require concrete cutting or trenching. It is not necessary to work inside ceiling space. There is flexibility in routing, and cable rerouting is easy. Low profile floors are only one to three inches in height. There is almost an unlimited number of possibilities for layout designs. It can be rapidly installed during construction, and business disruption is minimized whenever additions and changes need to be made.



Disadvantages


The method takes up space of one to three inches in height. There will be an extra step in the installation process.



Union Network Cabling


When union work requires a unionized cabling group, call on Union Network Cabling for your commercial Cat5e/6/6a and fiber cabling projects. Specializing in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290

Network Cabling,data cabling,,DC

Comparing Cat 7 to the Other Cats

3 Mar 2017

Data cabling, network cablingNowadays offices and homes utilize either a wireless (Wi-Fi) connection or wired network connection. Usually faster than Wi-Fi, wired connections also have lower latency. These two types of network connection continue to progress technologically, providing users ever increasing speeds.


In the case of home networks, the speed of the internet connection is typically the issue, and the cabling may not be a factor. However, a company must consider the specifications of particular cables and how these would meet its requirements in order to properly decide which to select. There can be a vast difference between the network speeds of the various Ethernet cables.



Types


Cables are differentiated by standard categories. Category has been abbreviated to “Cat” by the industry. Currently, the most common cables in use are Cat 5, Cat 5e, Cat 6, and Cat 6a. The newest type is Cat 7. Every type is backward compatible, allowing users to insert a newer cable into a device that was manufactured for an older cable without any compatibility issues arising.

Progress


With every new cable category, users were provided increased speed and decreased crosstalk. Newer category cables provided faster speeds at increased lengths of cable. The following offers comparisons at 100 meters of cable, illustrating the differences between the ethernet cable categories:

Cat 5 - Considered slow and inadequate for business networks, providing up to 100 Mb/second at 100 Mhz.

Cat 5e - provides up to 1 Gb/second internet speed at 100 Mhz.

Cat 6 -provides up to 1 Gb/second, and cable lengths up to 55 meters can give internet speeds of 10 Gb/second at 250

Cat 6a -can provides speeds up to 10 Gb/second, to 100 meters of cable length, at 500 Mhz.

Cat 7 - provides speeds up to 10 Gb/second to 100 meters of cable, at 600 Mhz.

History


Cat 5 was the standard in 1995, Cat 5e became standard in 2001, and Cat 6 was introduced in 2002. Arriving in 2008, Cat 6a is typically the newest cable the majority of companies have used because it is not considered necessary to update to Cat 7 yet. Cat 7a and Cat 8, which were respectively released in 2010 and 2013, are still waiting in the wings.

Union Network Cabling


When union work requires a unionized cabling group, call on Union Network Cabling for your commercial Cat5e/6/6a and fiber cabling projects. We specialize in cabling for data, voice, security and even the latest WiFi and LiFi solutions. Phone: (202) 462-4290
Cat5e Cat6/6a Cabling,cable installations

What is Certification and is it really necessary?

10 Aug 2015

Environmental Problems with Cat5e, Cat6, and Cat6A Cable


Cable must be installed so that external environmental factors do not have an effect on the performance of the network. Problems can occur at the patch panel punch down, at the wall plate jack and anywhere along the cable itself. Maybe an inadvertent kink is in the cable. Or there is a snag in the cable as it got pulled across a rough surface in the rafters above the drop ceiling. Or maybe the cable got too close to an electric line. Any one of these issues can degrade the performance of an individual cable.


There are two basic kinds of testing that is performed during the installation of cabling:




  1. Continuity Testing

  2. Certification


Continuity Testing



Continuity Testing is a test to insure that the wires in the connectors at the faceplate and at the patch panel are connected up correctly. There are 4 pairs of wires and each wire is color-coded. So, as the technician is connecting everything, a particular sequence is required. If a wire is connected in the wrong order, the cable will fail. This is a basic wire-mapping test. If this test fails, the connector and wires are re-examined and re-terminated. All of our cable installations include continuity testing.


But the only way to insure and guarantee full speed to every cable is to do Certification Testing on each cable.



Certification



Certification Testing is a performance test that utilizes a precision device that sends a signal from one end of the cable to the other. This test is the only way to test the data-carrying capacity of each cable. For example, Cat6A cable is rated to run at 10G/sec. But if you have an issue, the cable will work but it might be running at a slower speed. It passes the continuity test but it's not performing at 100%. Certification will find the fault, pin-pointed to its exact location so that our technician can fix it, retest it and fully certify it as 100% top-speed rated.


The Fluke DSX-5000 is a very expensive test device that we employ to test and certify our cabling jobs. It costs about an extra $10 per cable to get everything tested and certified. But without this test, we can't guarantee top speeds throughout your network. And, considering that most cabling projects have a useful lifespan of 15 - 20 years, this investment upfront is very cost-effective. It means you will have full speed to every device for the entire lifetime of your cabling infrastructure.


Certification includes a PDF report showing every cable and the test results.


Do you have an upcoming cabling project?




Is it Practical to Use Cat6 Cable?

26 Apr 2015

cat 6,structured cabling, Data CablingData volume has grown extensively. Also, the processing capacity to users continues to get grow. Specialists in data management forecast that information production will be 44 times larger in five years with enterprises needing to process and safeguard 80 percent of the new data.



Data Cables


For these reasons, you might need to become more familiar with different types of cabling. There is Category 5 (Cat5) cable but it is only capable of transmitting 1000 megabits data rate per second on an Ethernet network. Transfer of data demands are increasing due to new and more sophisticated applications. That is why many companies prefer to work with Category 6 (Cat6) cables. Cat6 has a maximum data transfer of 10,000 megabits per second. Cat6 is also backward compatible which means your Cat5 connectors will plug i and work (at the lower speeds).



Future Proofing


Cat6 infrastructure guarantees that your system will be relevant well into the future. This allows users to easily cope with any modifications, new features or technological developments. The Cat5 standard has been used for a long time. However, your enterprise needs adequate bandwidth to handle these continuing and future changes. It is not merely a possibility or “let's say” situation. It is to be anticipated as the online experience continues to progress.


Demand for Cat6 escalates as the world-wide web is now offering premium video streams, online applications, highly-responsive and media-heavy portals.  If you decide to upgrade to a more reliable network, consider Cat6 cables. It is fast becoming the new standard in this industry.



Downsides


Cat 6 is more costly compared to Cat5e cables. On average, we are finding that projects cost about 20-25% more. This is because you are not guaranteed full speed unless all the components operate at gigabit speed. So, you need Cat6 cable, connectors, patch panels and Gigabit switches too. If one part is not rated as gigabit, the network will run at Cat5e speeds. Call or contact us to help you make this decision.


Nevertheless, experts say Cat6 will sooner or later surpass Category 5e.  And the initial upfront costs will pay future productivity gains for many, many years to come.

 

Directions in Telecommunications and Cabling

3 Apr 2015

 Data Cabling ,Network cabling, DCThe telecommunications industry continues to advance. And bandwidth demands will continue to increase. Meanwhile, conditions to convey considerable amounts of information quickly are changing. Applications including graphic information, technical modeling, video conferencing, and multi-level online databases will certainly increase bandwidth requisites. The bottom line is demand for higher transfer speed for information is expected to rise.



Properties for Cabling Systems


Two principal properties needed for cabling systems are performance and easy installation. Fiber and shielded twisted-pair provide stronger signals compared to Unshielded Twisted Pair (UTP) although these two lagging in client acceptance. The question is will UTP provide the appropriate bandwidth for modern applications?



Unshielded Twisted Pair


UTP is considered the most prevalent cable worldwide for telecommunications and networking. Cat 5e is the most popular and it long ago replaced coaxial cable which failed to keep up with more dependable and faster networks. UTP is also easy to install, develop and troubleshoot. Unshielded Twisted Pair cabling does not have any foil covering. It depends on twisted pairs inside the cable to prevent electromagnetic interference. UTP is used extensively for local area networking and comparable cabling configurations. Hence, installation is easier and less expensive.



Shielded Twisted Pair


Shielded twisted Pair (STP) features a metallic foil enclosing twisted wire pairs inside the cable. This is the safeguard against electromagnetic intervention which facilitates rapid data transmission. STP functions by drawing electromagnetic interference and counterbalancing this with grounded cabling. The drawback is that if the cable is not grounded correctly it loses the capacity to prevent unnecessary noise. STP is also larger and more sensitive compared to UTP cables. Expert cable installers use this cabling for industrial environments where adjacent equipment emit significant amounts of elctron-magnetic interference (EMI). Actually, UTP and STP can perform well if installed and maintained by efficient cabling providers.



Transmission is Essential


Transmission should be balanced. This is the standard for conduction of data using twisted cabling pairs. Separate protection for balanced twisted pairs is designed to enhance resistance and emission of the communication lines. The shielding method produces a conductive barrier that lessens these electromagnetic waves. It also creates a conduit for conduction so that currents and can pass data through without any obstruction. Shielding can be performed on individual pairs or as one set of pairs.


Please contact us if you have any questions or concerns or if you need a free quote on your cabling project.